Use window before FFT
PostPosted: Tue May 26, 2015 7:09 am Reply with quote
Niick
Member
 
Joined: 07 May 2015
Posts: 25
Location: Portland, OR USA




when "use window before FFT" is applied, is the applied window then just at the very beginning and very end of the full length FFT, in other words, when I select "widowed" instead of "full", and then select User Defined for left or right hand window marker, does adjusting that window have any bearing on the "before FFT" window? I didn't think that it did, just want to make sure. Also, am I correct then in thinking that the "before FFT" window is a Tukey 50% at the beginning and end of whatever FFT length you've chosen for your measurement, and is unaffected by the "windowed" or "full" selection and user defined variables? That they are essentially 2 separate windows?
View user's profile Send private message
PostPosted: Tue May 26, 2015 9:53 am Reply with quote
Waldemar
Member
 
Joined: 05 Dec 2005
Posts: 112




Hello Nick,
yes there are two different windows.
The Option "Use Window before FFT" is only for the FFT of the input. It is used the for every FFT of the length chosen in the FFT Size (Parameters window). Yes it is done at the beginning and at the end of every FFT length.
The selection at the right (Full / Windowed) is in the other context of the window chosen here manually.

_________________
Best Regards
SDA, Waldemar Richert
View user's profile Send private message
AFMG Network Forum Index -> AFMG SysTune
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum
All times are GMT  
Page 1 of 1  

  
  
 Post new topic  Reply to topic  


Powered by phpBB © 2001-2003 phpBB Group
Theme created by Vjacheslav Trushkin
Variation by CodeWeavers and AFMG