AFMG Network
Forums for AFMG Software
AFMG Network Forum Index
Search found 143 matches
Negative volume nightmare
PostForum: EASE - Discussion   Posted: Thu Mar 14, 2019 12:43 pm   Subject: Negative volume nightmare
Frank Siegmann
 
Replies: 5
Views: 72




You can send your project to support@afmg.eu for checking.
Negative volume nightmare
PostForum: EASE - Discussion   Posted: Wed Mar 13, 2019 3:14 pm   Subject: Negative volume nightmare
Frank Siegmann
 
Replies: 5
Views: 72




You need to change the orientation of all faces so they are facing in (the yellow side) instead of out of the room. The easiest way to correct this is to reverse the orientation of one face, keep that ...
When to use signal masking and what is the definition of it?
PostForum: EASE - Discussion   Posted: Tue Mar 05, 2019 9:47 am   Subject: When to use signal masking and what is the definition of it?
Frank Siegmann
 
Replies: 1
Views: 95




Please see the International Standard IEC 60268-16.
Ease focus 3 sound source issue
PostForum: EASE Focus   Posted: Mon Feb 04, 2019 1:53 pm   Subject: Ease focus 3 sound source issue
Frank Siegmann
 
Replies: 1
Views: 117




Please try restarting Focus 3 using Default Settings from the Windows Start Menu under All Programs > AFMG > EASE Focus 3.
Do GLL files act as a point source?
PostForum: EASE - Discussion   Posted: Mon Jan 07, 2019 2:12 pm   Subject: Do GLL files act as a point source?
Frank Siegmann
 
Replies: 1
Views: 213




Yes, for ray tracing each cabinet of a line array is considered separately as source.

Frank Siegmann
AFMG
loudspeaker sensitivity convention
PostForum: EASE - Discussion   Posted: Mon Dec 03, 2018 9:20 am   Subject: loudspeaker sensitivity convention
Frank Siegmann
 
Replies: 1
Views: 249




For GLLs b) is the right answer.

Frank Siegmann
EASE Address Crashes at boot
PostForum: EASE Address   Posted: Thu Oct 18, 2018 8:40 am   Subject: EASE Address Crashes at boot
Frank Siegmann
 
Replies: 1
Views: 651




Hello Krokkor,

look for the folder

c:\Users\<USER>\AppData\Local\AFMG\

and delete all EASE Address sub-folders.

This will setup EASE Address to default.

Frank Siegmann
AFMG
Total SPL - freq graph vs mapping area, inconsistent
PostForum: EASE - Discussion   Posted: Mon Oct 15, 2018 12:44 pm   Subject: Total SPL - freq graph vs mapping area, inconsistent
Frank Siegmann
 
Replies: 2
Views: 799




Hi Micko,

please note that the average SPL is the average value for all calculation (receiving) points. So there is only one value per frequency band per area.

To check then differences you get ...
STI - Consider Noise Levels (why!?)
PostForum: EASE - Discussion   Posted: Fri Aug 24, 2018 8:51 am   Subject: STI - Consider Noise Levels (why!?)
Frank Siegmann
 
Replies: 2
Views: 943




No, only this option enables S/N correction for calculation of STI and derived measures according to IEC 60268-16.

Frank Siegmann
AFMG
how to simulate the wind from the sea into the building
PostForum: EASE - Discussion   Posted: Wed Aug 15, 2018 12:30 pm   Subject: how to simulate the wind from the sea into the building
Frank Siegmann
 
Replies: 1
Views: 847




You could use a corresponding ambient noise level for the STI calculation which represents the wind.

Frank Siegmann
AFMG
Floor coupling for subwoofer arrangement
PostForum: EASE Focus   Posted: Tue Jul 17, 2018 10:06 am   Subject: Floor coupling for subwoofer arrangement
Frank Siegmann
 
Replies: 1
Views: 992




Hello Hosung,

floor coupling and ground or side wall reflections are not considered.

Best Regards
Frank Siegmann
Rotating loudspeaker doesn't change dispersion in top view
PostForum: EASE Focus   Posted: Wed Jul 04, 2018 11:35 am   Subject: Rotating loudspeaker doesn't change dispersion in top view
Frank Siegmann
 
Replies: 2
Views: 1221




If possible please send your EASE Focus project to our technical support at AFMG ( support@afmg.eu ) for checking.

Frank Siegmann
Negative dB levels for some wall mounted sources
PostForum: EASE Evac   Posted: Thu Jun 21, 2018 8:33 am   Subject: Negative dB levels for some wall mounted sources
Frank Siegmann
 
Replies: 1
Views: 1033




It would be helpful if you could send your EASE Evac project for checking to our technical support at support@afmg.eu

Best Regards
Frank Siegmann
AFMG
How to show dB coverage cones with .GLL files?
PostForum: EASE - Discussion   Posted: Wed May 23, 2018 10:16 am   Subject: How to show dB coverage cones with .GLL files?
Frank Siegmann
 
Replies: 2
Views: 1641




Hi Masaya,

for GLL type files coverage cones are not available like for the old spk format files.

Frank Siegmann
AFMG
All to Max = 1 Watt
PostForum: EASE - Discussion   Posted: Mon Apr 23, 2018 12:10 pm   Subject: All to Max = 1 Watt
Frank Siegmann
 
Replies: 1
Views: 1663




Hi Charles,

please note that AFMG is not responsible for this data. If you have questions regarding accuracy, completeness or up-to-dateness please consult the loudspeaker manufacturer.

Best Reg ...
Page 1 of 10 Goto page 1, 2, 3, 4, 5, 6, 7, 8, 9, 10  Next
All times are GMT
  


Powered by phpBB © 2001-2003 phpBB Group
Theme created by Vjacheslav Trushkin
Variation by CodeWeavers