PostPosted: Wed Apr 20, 2005 8:40 pm Reply with quote
Stefan
Member
 
Joined: 19 Apr 2005
Posts: 167
Location: Berlin, Germany




To show 1/3rd octave mappings and levels you will need to switch the function on under Options [F9]. The default is OFF since v1.04, mainly to prevent from misunderstandings of the initial displays.

Generally 1/3rd octave level predictions should be understood as indicators for problems like comb-filtering but not as quantitatively absolutely correct numbers.