AFMG Network Forum
AFMG Network Forum Index -> EASE 4 -> Impact tracing time frame in open room w/ neglible RT
Post new topic  Reply to topic View previous topic :: View next topic 
Impact tracing time frame in open room w/ neglible RT
PostPosted: Tue Aug 15, 2006 11:43 am Reply with quote
Varun
Member
 
Joined: 08 Aug 2006
Posts: 14




Hi All,
How do you estimate the time frame for an open room that has neglible RT.
A particular model of mine i.e a 20,000 capacity stadium has 0 RT.
From what I know , this is quite normal when large rooms are open and EASE cannot determine the room volume due to lack of definite surfaces.
In this case, my mean free path time is 0 s.
By rule of thumb, time frame should be roughly (mean free path time * order).
When this is incalculable as in my case, how do you decide as to what would be a suitable time frame / order and no. of rays for generating a realistic reflectogram?
View user's profile Send private message
PostPosted: Fri Aug 25, 2006 11:38 pm Reply with quote
Jim Mobley
Member
 
Joined: 27 Jul 2005
Posts: 134
Location: Foothill Ranch, California, USA




Hi Varun,

You can do a first-order Mirror Impact study and look at the arrival times in the Probe. A first order mirror calculation shouldn't take more than a minute of two.

_________________
Best regards,

Jim Mobley
Sr. Application Engineer
Renkus-Heinz, Inc.
19201 Cook St.
Foothill Ranch, CA 92610 USA
TEL: +1-949-588-9997
FAX: +1-949-588-9514
www.renkus-heinz.com
mailto:jim@renkus-heinz.com
View user's profile Send private message Send e-mail Visit poster's website
AFMG Network Forum Index -> EASE 4
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum
All times are GMT  
Page 1 of 1  

  
  
 Post new topic  Reply to topic  


Powered by phpBB © 2001-2003 phpBB Group
Theme created by Vjacheslav Trushkin
Variation by CodeWeavers and AFMG