AFMG Network Forum
AFMG Network Forum Index -> AFMG EASERA -> Bug in the Phase view
Post new topic  Reply to topic View previous topic :: View next topic 
Bug in the Phase view
PostPosted: Thu Dec 15, 2005 11:54 am Reply with quote
Tobi @ Fohhn Audio AG
Member
 
Joined: 25 Oct 2005
Posts: 13




Hi everyone of SDA,
it´s a problem to watch the Phase in a linaer scale.
Everytime I switch from the log. into the lin. scaled Phase, there is a warning like: „Error :6 Überlauf Trace:1 “ , and I have to restart EASERA to work along.
Please eliminate this bug, to make this basic application usable.
Thank you

Best regards
Tobi
View user's profile Send private message Visit poster's website
Re: Bug in the Phase view
PostPosted: Thu Dec 15, 2005 5:21 pm Reply with quote
Bruce
Member
 
Joined: 19 Apr 2005
Posts: 459
Location: Minneapolis, MN, USA




Hallo Tobi,
Tobi @ Fohhn Audio AG wrote:
Hi everyone of SDA,
it´s a problem to watch the Phase in a linaer scale.
Everytime I switch from the log. into the lin. scaled Phase, there is a warning like: „Error :6 Überlauf Trace:1 “ , and I have to restart EASERA to work along.

I am unable to reproduce this. Does it happen when you try it on any of the Sample files? You can find them in the folder EASERA10DATA\Samples\Measurements.

_________________
Best Regards,
Bruce C. Olson
View user's profile Send private message Send e-mail Visit poster's website
PostPosted: Fri Dec 16, 2005 11:57 am Reply with quote
Tobi @ Fohhn Audio AG
Member
 
Joined: 25 Oct 2005
Posts: 13




Hi Bruce
hmm, strange...
...meybe with a better example: When I watch the linear unwrapped Phase of a processed impulse response of a speaker measurement, turn then to the wrapped Phase ( or Magnitude ) view without switching the scale back to log. Scale, I get this Error.
What Sample File do you mean ? I can´t find the folder „EASERA10Data/Samples/Measurements“, only the folder „EASERA10Data/ Soundsamples/ *.* “ but this is full of *.wav Files.

Best regards
Tobi
View user's profile Send private message Visit poster's website
PostPosted: Fri Dec 16, 2005 9:39 pm Reply with quote
Bruce
Member
 
Joined: 19 Apr 2005
Posts: 459
Location: Minneapolis, MN, USA




Tobi @ Fohhn Audio AG wrote:
When I watch the linear unwrapped Phase of a processed impulse response of a speaker measurement, turn then to the wrapped Phase ( or Magnitude ) view without switching the scale back to log. Scale, I get this Error.


Ahha, now I see it. Thank you.

_________________
Best Regards,
Bruce C. Olson
View user's profile Send private message Send e-mail Visit poster's website
AFMG Network Forum Index -> AFMG EASERA
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum
All times are GMT  
Page 1 of 1  

  
  
 Post new topic  Reply to topic  


Powered by phpBB © 2001-2003 phpBB Group
Theme created by Vjacheslav Trushkin
Variation by CodeWeavers and AFMG