AES + SPDIF measurements
PostForum: AFMG EASERA   Posted: Tue Jan 03, 2012 6:44 pm   Subject: AES + SPDIF measurements
datrobban
 
Replies: 2
Views: 22189




Hi Bruce!
Thanks for your support! I'll have a look at Aubion and see if it will work

Best regards
Robert Nilsson
AES + SPDIF measurements
PostForum: AFMG EASERA   Posted: Tue Jan 03, 2012 8:27 am   Subject: AES + SPDIF measurements
datrobban
 
Replies: 2
Views: 22189




Hi!
Does any one now any interface or solution to measure AES and SPDIF signal with either Easera or Systune?
NTI has Digilyzer DL1 for this but it would be nice to use the measuring units that you ...
can't open Clipboard
PostForum: AFMG EASERA   Posted: Thu Apr 08, 2010 11:45 am   Subject: can't open Clipboard
datrobban
 
Replies: 1
Views: 22743




Hi!
I have Easera 1.1.3 on 2 computers. 1 is a dell Latitude D820 which i use to do most measurements with. WXP SP3 3GB. Om both my computers i often get this error message: Run-Time-error '521': Can ...
correcting measured STI for influence of background noice
PostForum: AFMG EASERA   Posted: Tue Mar 24, 2009 9:06 am   Subject: correcting measured STI for influence of background noice
datrobban
 
Replies: 1
Views: 8640




Hi!

I need to report the measured STI value, corrected for the influence of background noice equal to NC30.
I've red the manual bud i didn't find a way to do this in Easera. Is this possible to do ...
STI according to IEC60268-16
PostForum: AFMG EASERA   Posted: Fri Jul 11, 2008 8:13 am   Subject: STI according to IEC60268-16
datrobban
 
Replies: 3
Views: 12329




Thanks Bruce!

could the time window for STI measurements have an option to be set according to IEC 60268-16? or what shall the time window size be according to IEC?

Best regards
Robert Nilsson
STI according to IEC60268-16
PostForum: AFMG EASERA   Posted: Thu Jul 10, 2008 12:52 pm   Subject: STI according to IEC60268-16
datrobban
 
Replies: 3
Views: 12329




Hi!

can anyone inform me if the default setup in EASERA for STI measurements is according to the 1998 or 2003 version of the IEC60268-16?

Bes tergards
Robert Nilsson
ETC topp level to 0dB
PostForum: EASE 4   Posted: Sun Feb 24, 2008 10:32 pm   Subject: ETC topp level to 0dB
datrobban
 
Replies: 0
Views: 8472




Hello all!

If you are calculating the ETC from either ray tracing or aura module, the ETC diagrams shows the real peak level, for instance peak 90dB. Is there a way to change the level to have the ...
Clipboard issue
PostForum: AFMG EASERA   Posted: Mon Jan 07, 2008 2:30 pm   Subject: Clipboard issue
datrobban
 
Replies: 3
Views: 11164




Hello Stefan!

Thanks for your support!

the systematics i've seen is this: Print screen and alt-print screen works.
If i start EASERA and open up 1 saved measurement (full IR) and use click on c ...
Clipboard issue
PostForum: AFMG EASERA   Posted: Sun Jan 06, 2008 3:57 pm   Subject: Clipboard issue
datrobban
 
Replies: 3
Views: 11164




Hello!

I have a Dell Latitude D820 XP SP2 with 1GB RAM
i have many times had problems with the clipborad function. I can click on the icon Clipboard and get the error message "Run time Error ...
Crest factor on Pink noice generator
PostForum: AFMG EASERA   Posted: Fri Dec 07, 2007 6:15 am   Subject: Crest factor on Pink noice generator
datrobban
 
Replies: 2
Views: 10106




Hello Bruce!

Thanks for your help! Surprised
Crest factor on Pink noice generator
PostForum: AFMG EASERA   Posted: Thu Dec 06, 2007 2:48 pm   Subject: Crest factor on Pink noice generator
datrobban
 
Replies: 2
Views: 10106




Hello!
Does any one know what the crest factor are in the pink noice generator in easera?

//Robert Nilsson
EASE signal source
PostForum: EASE 4   Posted: Wed Nov 15, 2006 8:38 pm   Subject: EASE signal source
datrobban
 
Replies: 1
Views: 9129




I have an acoustical consultant who demands to have it confirmed in a report from me, what are the official signal Source used in SPL calculations and in the AURA module?
Does it follow any standard ...
Lambert diffusion i %
PostForum: EASE 4   Posted: Wed Nov 15, 2006 8:35 pm   Subject: EASE signal source
datrobban
 
Replies: 2
Views: 11348




I have an acoustical consultant who demands to have it confirmed in a report, what are the official signal Source used in SPL calculations and in the AURA module?
Does it follow any standard and does ...
Lambert diffusion i %
PostForum: EASE 4   Posted: Mon Nov 06, 2006 5:57 pm   Subject: Lambert diffusion i %
datrobban
 
Replies: 2
Views: 11348




I have recived Lambert diffusion in % in octaveband between 125-4000 Hz.
Does anyone know if those values are directly transferable into EASE 4.1 Wall material database or do i have to handle it in ...
(RA)STI to CIS converting
PostForum: AFMG EASERA   Posted: Mon Sep 12, 2005 1:58 pm   Subject: (RA)STI to CIS converting
datrobban
 
Replies: 1
Views: 9551




Hi!

In sweden we some time have to measure and report to the CIS (common intelligibility scale)is there any planned calculation (converting) to the CIS scale from the STI in the near future in EASE ...