Hi Bruce,
I have creaeted a Weighted Sweep with 48kHz Sample Rate, 5,5s length, from 10Hz to 24 kHz with a Magnitude of 0dB, saved this and compared this to the Standard Weighted Sweep (System Signa ... |
|
|
|
|
Hi Bruce,
thanks for your fast reply.
OK, I have watched the magnitude of my created Weighted Sweep and everything seems to be fine...But when I lisen to this signal it seems to be completly differ ... |
|
|
|
|
Hi everyone of SDA,
I think there is a Bug in the Signal Generator Funktion, because, it is not possible to create an real Weighted-Sweep-Stimulus.
I can create this but it always sounds like a W ... |
|
|
|
|
Hi Bruce
hmm, strange...
...meybe with a better example: When I watch the linear unwrapped Phase of a processed impulse response of a speaker measurement, turn then to the wrapped Phase ( or Magnitu ... |
|
|
|
|
Hi everyone of SDA,
it´s a problem to watch the Phase in a linaer scale.
Everytime I switch from the log. into the lin. scaled Phase, there is a warning like: „Error :6 Überlauf Trace:1 “ , and I ... |
|
|
|
|
Hi everyone,
I always get a warning like „Bad Determination of Delay-Time“ on every measurement.
I knew that I can switch this kind of warning off, but how can I eliminate the reason ?
And what i ... |
|
|
|
|
Hi,
how can I measure the absolute SPL of different loudspeakers with EASERA, e.g. 1W at one meter on a 4Ohm Speaker ??
Tobi |
|
|
|
|
Hi,
I think it would be helpful to make the settings in the Waterfall / Spektrogram section saveable.
They all get lost when I reopen this section from the View & Calc Window.
I also miss a ... |
|
|
|
|
Hi everyone,
Why isn´t EASERA saving things like „Hardware Compensation“, „Digital Output Gain“ or „Measurement Notes“ in a user-defined Measurement Setup ?
And another problem for me is how I can s ... |
|
|
|
|
Hi Stefan,
the first thing I have done after the installation of my brand new FireBox, was muting the MIC 1 & 2 channel in the FireboxMixer. After that I wanted to measure a frequency response o ... |
|
|
|
|
Hi everyone,
this is a warning for everybody who uses the FireBox: Be sure you have switched off the 48V Phantom power befor you loop the output back to the MIC input to make a Referencefile or a Vol ... |
|
|
|
|
Hi,
I need this impedance measurement for my speakers too.
Another idea beside the vertical Ohms-scale could be a little dialog box where I can tell EASERA the value of my connected measurement re ... |
|
|
|
|
Hi everyone,
how can I estimate the validity of the FFT at low frequencys, depending on the markerd area at the Impuls response.
Our old measuring system ( MLSSA ) shows me the area where the FFT is ... |
|
|